Advanced Safety Features
1. PISTON SYSTEM TEHNOLOGY ( FIRST IN SEGMENT )
The precisely designed Piston System Technology for mixing Nitrous Oxide and Oxygen ensures long-term machine use. Unlike diaphragm system-based machines, this technology eliminates the risk of improper gas mixing caused by diaphragm wear, offering enhanced reliability and performance
2. MAX OXYGEN FLOW LIMITER ( FIRST IN SEGMENT )
The Niox Conscious Sedation unit has a maximum oxygen flow limiter that prevents the flow from exceeding 10-15 liters per minute. This feature ensures safe oxygen delivery and helps prevent hyperoxia during the procedure, enhancing patient safety.
3. NITROUS OXIDE DEPRESSURISING BUTTON ( FIRST IN SEGMENT )
This feature allows users to independently close the nitrous oxide cylinders and depressurize the nitrous oxide supply during emergencies, without interrupting the continuous oxygen flow to the patient. It also ensures the safe dismantling of nitrous oxide cylinders.
4. NON RETURN VALVE AT YOKE
A Non-Return Valve (NRV), or check valve, allows gas to flow in only one direction. The NRV in the yoke prevents gas from flowing between cylinders if both are opened simultaneously, ensuring each cylinder operates independently and enhancing safety.
5. AIR FILTER AT AIR OUTLET
An air filter at the head unit's outlet prevents particles and moisture from entering the breathing circuit, ensuring only clean, dry air is delivered to the patient for enhanced safety and comfort during sedation.
6. SCAVENGING SYSTEM
The attached or inbuild scavenging system in Niox nitrous oxide sedation machine safely removes excess gas, preventing accidental exposure to healthcare providers and patients, and ensuring a safer environment during procedures.
Basic Safety Features
6. OXYGEN FAIL SAFETY SYSTEMS
The Oxygen Fail Safety System ensures that if the oxygen supply fails during a procedure, Nâ‚‚O delivery is automatically stopped, preventing the administration of Nâ‚‚O without oxygen.
7. NITROUS OXIDE CONCENTRATION LIMITER
The nitrous Oxide Concentration limiter, restricting N₂O concentration to a safe 70% when mixed with oxygen. This ensures a balanced, safe mixture, reducing the risk of hypoxia and maintaining proper oxygen levels during sedation.​
8. 30 % 0F OXYGEN CONCENTRATION ASSURANCE
The Niox Conscious Sedation unit maintains a minimum oxygen level of 30%. This key safety feature ensures that patients receive adequate oxygen during sedation, enhancing their safety and comfort.
9. PIN INDEX SAFETY SYSTEM
The Niox Nitrous Oxide Conscious Sedation machine is equipped with a precise configuration of pins and holes that facilitates secure connections between nitrous oxide (Nâ‚‚O) and oxygen (Oâ‚‚) gas cylinders. This carefully designed system effectively prevents the accidental interchange of gases
10. DIAMETER INDEX SAFETY SYSTEM
The Niox Nitrous Oxide Conscious Sedation machine uses standardized connections with different diameters to prevent the accidental interchange of nitrous oxide (Nâ‚‚O) and oxygen (Oâ‚‚), ensuring each gas connects only to its correct regulator and pipe.
11. OXYGEN FLUSH WITH DEPRESSURISING BUTTON
This feature enables rapid delivery of 100% oxygen in emergencies, ensuring a quick response. Combined with the oxygen depressurizing button, it allows efficient release of residual gases and safe dismantling of Oxygen cylinders.
12. EMERGENCY AIR INTAKE VALVE
This vital safety feature ensures patient care during sedation by allowing immediate intake of ambient air in case of a gas supply failure or critical situation, ensuring adequate ventilation.
13. NON REBREATHING VAVLE AT HEAD UNIT
This valve allows for one-way airflow, enabling patients to inhale fresh gas while preventing the exhaled gases from being re-inhaled.
MACHINE FEATURES
1. L TYPE CYLINDER HOLDER
The L-shaped cylinder holder securely holds gas cylinders in place, allowing for easy mounting and dismounting. This design also acts as a safeguard, preventing accidental back collision of the cylinders, ensuring safety.
2. SOLID AND RIGID CONSTRUCTION.
The solid and rigid construction, ensuring it is durable and reliable during use. This strong design reduces vibrations, providing a stable platform for safe sedation.
3. KNOBS FOR TITRATION AND FLOW CONTROL.
​The knobs for titration and gas flow control, allowing healthcare providers to easily adjust the levels of nitrous oxide and oxygen. These user-friendly knobs enable precise control over gas delivery, ensuring that patients receive the appropriate sedation levels for their needs.
4. 70° INCLINED HEAD UNIT.
The 70° inclined head unit offers an optimal view of the flow meters and control knobs, allowing healthcare providers to easily monitor and adjust settings during procedures. This design enhances visibility, accessibility, and efficiency in patient care.
5. 70° INCLINED PRESSURE GAUGES.
The 70° inclined pressure gauges provide an optimal view of pressure readings, allowing healthcare providers to monitor levels comfortably without leaning in.
6. ATTRACTIVE AND UNIQUE DESIGN.
The Niox Conscious Sedation unit’s sleek, modern design enhances both aesthetics and functionality. Its well-arranged components ensure easy access to controls, making it a standout choice for sedation procedures.
7. METAL DIAPHRAGM REGULATORS.
The metal diaphragm regulators prevent wear and tear common with rubber diaphragms, ensuring consistent performance and enhanced reliability over time.​
8. COLOUR CODED FLOW METERS.
The Color-coded flow meters make it easy to distinguish between nitrous oxide (N₂O) and oxygen (O₂), allowing healthcare providers to quickly monitor flow rates and reduce errors.​
9. COLOUR CODED YOKE.
The color-coded yoke enhances safety by clearly matching each side with the corresponding gas cylinders, allowing healthcare providers to easily identify connections and minimize misconnection risks.
10. STAINLESS STEEL REGULATORS
The Stainless steel regulators offer durability, corrosion resistance, and precise gas control, ensuring safe and effective delivery of nitrous oxide and oxygen during sedation procedures, even with repeated use.
11. STAINLESS STEEL PRESSURE GAUGUES
​The Stainless steel pressure gauges are durable, corrosion-resistant, and provide accurate readings over time. Their reliable performance and low maintenance make them an ideal choice for monitoring gas pressures during sedation procedures, ensuring safety and effectiveness.
12. STAINLESS STEEL HANDLE
The T-shaped stainless steel handle enables easy rotation of the clamping bolt, ensuring a secure fit between the cylinder and yoke with minimal effort. Its durable construction guarantees long-lasting performance in clinical settings.
13. COMPACT SUPPORT STAND WITH STYLISH BASE
The The compact, rigid stand features a stylish four-spoke leaf design with wheels and stoppers for stability. Its adjustable height offers flexibility and convenience, combining aesthetics with robust support
​14. HIGH STRENGTH WHEELS.
Premium wheels with integrated stoppers provide smooth movement and secure locking, ensuring stability and enhancing safety and convenience during procedures.
​15. STAINLESS STEEL STOP PLUG
The Stainless steel stop plugs provide reliable sealing, prevent gas leakage, and ensure secure connections. Their corrosion-resistant design ensures durability and long-term use in clinical environments.
​16.REBREATHING BAG
The rebreathing bag provides visual feedback on the patient's breathing, expanding and contracting with each breath, allowing clinicians to monitor respiratory effort.
​17. HIGH STRENGTH CYLINDER HOLDER
High-strength stainless steel dowel pins securely hold Type A cylinders with a pin index valve, ensuring safe and reliable connections.
​18. PREMIUM AUTOCLAVABLE MASK
The Premium medical-grade silicone mask with a curved edge seal ensures leak-proof performance during procedures, enhancing safety and effectiveness.
​19.PREMIUM AUTOCLAVABLE CIRCUIT
The Premium medical-grade silicone breathing circuit with a twin-valve mask top cap features dedicated valves for inhalation and exhalation, ensuring optimal scavenging and superior performance for the machine.